How to activate HSE monitoring

Revision as of 10:54, 17 June 2024 by Registered User (→‎How to activate the monitoring)
Applicable for STM32MP13x lines, STM32MP25x lines

1. Article purpose[edit source]

The purpose of this article is to explain how to monitor the HSE oscillator.

If the HSE oscillator is used in the clock tree, it is possible to enable a monitoring function to detect and avoid over frequency. The LPTIM mechanism can detect any over frequency and triggers a tamper event which runs the appropriate custom actions.

2. How to activate the monitoring[edit source]

By default, the HSE monitor is disabled in the dtsi "SoC" files.

To activate the HSE monitor, add this node in your board OP-TEE device tree

	&hse_monitor {
		status = "okay";
	};

The LPTIMER used for HSE over frequency monitoring has to be enabled in counter node and to be assigned to the Arm® Cortex®-A secure context (OPTEE).

  • lptimer3 on STM32MP13x lines More info.png with:
&lptimer3 {
	status = "okay";
	counter {
		status = "okay";
	};
};
  • lptimer1 on STM32MP25x lines More info.png with:
&lptimer1 {
	status = "okay";
	counter {