There are 1 incomplete or pending task to finish installation of Semantic MediaWiki. An administrator or user with sufficient rights can complete it. This should be done before adding new data to avoid inconsistencies.1. Article purpose[edit source]
The purpose of this article is to explain how to monitor the HSE oscillator.
If the HSE oscillator is used in the clock tree, it is possible to enable a monitoring function to detect and avoid over frequency. The LPTIM mechanism can detect any over frequency and triggers a tamper event which runs the appropriate custom actions.
2. How to activate the monitoring[edit source]
By default, the HSE monitor is disabled in the dtsi "SoC" files.
To activate the HSE monitor, add this node in your board OP-TEE device tree
&hse_monitor {
status = "okay";
};